Measures · Reinforced concrete column

Reinforced concrete column pre-sizing FREE

Work out the section of a reinforced concrete column from its tributary area and floors. Below the result you find the formula and the standard.

Indicative pre-sizing. It does not replace a structural calculation signed by a licensed engineer. For seismic zones with agS (design ground acceleration) > 0.15g, long spans or use classes III/IV → talk to a structural engineer.
Pick a calculation from the list to start.

Formula, example and standard

N = A · n · q → A_pil = N / (0.5·fcd)

Example with the starting values (Tributary area: 20 m²; Floors above: 2; Total load q: 10 kN/m²): Min section 30×30 cm. Load N ≈ 400 kN · theoretical area 565 cm².

Source: NTC 2018 §7.4.6 · studiomadera.it

Indicative pre-sizing: it does not replace a calculation signed by a licensed engineer.